Skip to content

Fluke Ti480Ultra, Ti401Ultra, Ti300Ultra Thermal Imagers

Key features

  • PE conductor can be tested for possible presence of dangerous voltage against earth
  • Perform Cable Simulation with the PP State rotary switch simulating current capabilities of charging cables
  • Perform Vehicle Simulation testinig various charging states
  • Simulate PE error (Earth fault)
  • Test in accordance with IEC/EN 61851-1 and IEC/HD 60364-7-722
Category:

Product overview: Fluke Ti480U Ti401U Ti300U Infrared Thermal Cameras

The Fluke Vison Series is one of the well-received infrared thermal cameras, from Ti200, Ti300, Ti400 to Ti480Pro Series, we listen to the voice of users all the way to iterate better product performance.

With the support of the new sensor, the Vison Series now gets into a “brand new stage” and makes a substantial progress in image quality, focus speed and test functions. While retaining the classic industrial design, it improves user experience and help users with practical work.

We believe that every day engineers are making things better around them, and Fluke is also striving for this common goal together with its users.

Key features

  • It is equipped with a new sensor and optical system, the imaging effect breaks the parameter limit, the image sharpness is further improved, the target is clearer, and the problem region is presented more clearly
  • UltraFocus focusing technology: effective focusing with image algorithm, it can automatically focus in 1 s according to the temperature difference in complex scenes; laser autofocus, free choice of test targets; continuous auto focus function makes inspection work easier
  • Up to 30Hz frame rate, the full range of “camera motion” for smooth and free observation, video recording without frame drop or lag
  • Temperature measurement range up to 1200 °C to verify higher process requirements and explore more R&D fields
  • Support up to 10x digital zoom, free screen zooming, check long-distance targets: high-voltage equipment, overhead pipelines, large mechanical equipment
  • SmartView IR software for PC to process thermal video, analyze data, export reports, and complete the final step of the job
  • Classic industrial design: inheriting the appearance design and material of the Vision Series, it is still comfortable to hold with one hand and easy to operate, and it is not easy to fatigue for long time use

Technical Specifications

Specifications: Thermal Imagers: Ti480U, Ti401U, Ti300U

Function Parameter Fluke Ti480u Fluke Ti401u Fluke Ti300u
Basic Parameters
IR resolution 640 × 480 640 × 480 384 × 288
SuperResolution 1280 × 960
Detector type Uncooled focal plane infrared detector
Thermal sensitivity (NETD)
@ 30 °C
50 mk (0.05 °C) 75 mk (0.075 °C) 75 mk (0.075 °C)
Spectral response 7 to 14 μm
Image frame rate 30 Hz 9/30 Hz 9/30 Hz
Lens Field of View (FOV) 25° x 19°
Spatial resolution (IFOV) 0.68 mrad 0.68 mrad 1.14 mrad
Minimum imaging distance 0.25 m 0.1 m
Lens focal distance f 24.8 f 15
Focus Auto / Manual Focus
Lens recognition Auto
Optional lens 2x telephoto lens
4x telephoto lens
Wide-angle lens
Digital Zoom 1-10x 1-10x 1-4x
Measurement Analysis
Temperature range -20 °C to 1200 °C -20 °C to 650 °C
Temperature measurement range -20 °C to 120 °C -20 °C to 120 °C
0 °C to 650 °C 0 °C to 650 °C
300 °C to 1200 °C
Intelligent range Yes Yes Yes
Temperature accuracy ±2 °C or 2%, whichever is greater (@ 23 °C ± 5 °C ambient temperature)
Temperature measurement area Spots: 16
Lines: 8
Areas: 12
Global temperature measurement correction Support emissivity, environment temperature, reflected temperature, relative humidity, temperature measurement distance, IR window (temperature and transmittance) correction
Area temperature measurement correction Yes
Area audible alarm Support high and low temperature alarm for the highest, lowest and average temperature of the area
Temperature rise function Reference temperature can be the highest, lowest, average or custom temperature of the area
On-Imager analysis The thermal photos or videos are directly analyzed in the Imager
Analysis software for PC SmartView IR
Image Display
Display Screen 3.5″ LCD, 640 × 480
Image mode Thermal image, visible image, PIP
Palettes Grey, Iron 10, IronRed, Rainbow, Grey10, GreyRed, MidGrey, Yellow and Rain
Palettes can be inverted
Support real-time palette preview and switching
Temperature span mode Support automatic adjustment of temperature span (min. 3 °C)
Support manual adjustment of temperature span (min. 2 °C)
The maximum and minimum value of temperature span can be selected by touch (min. 2 °C)
Color and audible alarm Yes. Above the temperature, below the temperature and between the temperature
Information displayed on the image Display the global maximum, minimum, average temperature and temperature measurement parameters
High/low temperature tracking Marking and automatically tracks high and low temperature points
IR-Fusion
Blending degree of a visual photo and an infrared thermal image 0% to 100%
Picture-in-Picture (PIP) Yes. The size, position and blending degree of infrared window can be adjusted
Shooting Function
Digital camera Industrial grade digital camera with 13-megapixel lens
Memory card Micro SD card, standard 32 GB; expandable to 64 GB, 128 GB
Shooting Mode Support single frame and time-lapse shooting
Image format .bmp .jpg
Screen freeze Support single frame shooting and fully-radiometric video recording Support single frame shooting Support single frame shooting and fully-radiometric video recording
Code scanning function Yes. A QR code and barcode can be scanned as a label
Annotation function Support voice, text and label annotation
IR-PhotoNotes 5 images 2 images 2 images
Fully-radiometric video recording Support thermal video recording for analysis Support thermal video recording for analysis
Non-fully-radiometric video recording Support thermal video, visible video recording (only for viewing, not for analysis) Support thermal video, visible video recording (only for viewing, not for analysis)
Video frame rate 1 Hz to 9/16 Hz 1 Hz to 9/16 Hz
Video Format .is5, .mp4 .is5, .mp4
Gallery Support viewing, editing and deleting captured thermal images and video files
Data Connection
Bluetooth connection Support BT4.2 LE
USB interface Type-A, USB 2.0
HDMI interface Mini HDMI interface, HDMI 1.4
Fully-radiometric video analysis via PC software Fully-radiometric video analysis via PC software
Remote display via software Yes
Remote operation via software Yes Yes
HDMI output Support connection to a display or a projector via the HDMI interface
Ancillary Function
Laser Yes
Temperature feature measurement Support measuring the length of the temperature measurement line; support measuring the rectangular and circular area of the temperature measurement area
LED torch/flashlight Support flashlight and flash mode
Power System
Battery type 7.2V, 19Whr lithium battery, replaceable and rechargeable on field
Battery life 2 to 3 hours/battery
(*Actual life depends on settings and usage)
Charge Mode 10-15 V DC charging
Charging time 2.5 hours to full charge
Energy saving management Auto screen-off
Battery charge Ti SBC3B Two Bay Battery Charger (100 V ac to 240 V ac, 50/60 Hz, included), or in-Imager charging. Optional 12 V automotive charging adapter.
External power supply Power adapter (110 to 220 V, 50/60 Hz AC power)
Reliability and Certification
Safety standard IEC 61010-1: pollution degree 2
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Industrial Electromagnetic Environment; CISPR 11: Group 1, Class A
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
Radio frequency 2400 MHz to 2483.5 MHz
Radio output power <100 mW
Laser IEC 60825-1, Class 2; 650 nm; <1 mW
Ingress protection rating IEC 60529: IP52
Drop test Designed for 1 m drop resistance
Physical Parameter
Operating temperature -10 °C to 50 °C
Storage temperature -20 °C to 50 °C, without battery
Relative humidity 0% to 95% (non-condensing)
Dimensions 27.9 cm x 12.2 cm x 17.5 cm
Weight 1215 g 1188 g
Warranty and Maintenance
Warranty 2 years
Recommended calibration period 2 years
Supported Languages
Supported languages Simplified Chinese, English, Japanese, Korean, Traditional Chinese
Optional Lenses
Lens name Field of view Minimum imaging distance
Standard lens 25° x 19° 0.1 m
Wide-angle lens 44° x 34° 0.1 m
2x telephoto lens 12° x 9° 1.0 m (Ti480U / Ti401U)、0.25 m (Ti300U)
4x telephoto lens 7° x 5° 1.0 m (Ti480U / Ti401U)、0.25 m (Ti300U)

Resources

Resources:

Thermal Imagers: Ti480U, Ti401U, Ti300U