Skip to content

59 MAX Plus Infrared Thermometer

Key features

  • Easy to handle infrared thermometer with precise laser targeting and 10:1 distance to spot ratio
  • Measures temperatures from -30°C to 500°C (-22°F to 932°F)
  • Provides IP40 rating for extra protection
  • Presents a large, backlit LCD display for easy viewing
  • Features a small, lightweight design that fits easily fits into your tool bag

The Fluke 59 MAX+ Infrared Thermometer delivers the precision you need to do your job accurately and within your budget. It features a 10:1 distance to spot ratio and precise single laser targeting for accurate and repeatable measurements. Use the Fluke 59 MAX+ to perform non-contact temperature measurements on transformers, motors, pumps, panels, breakers, compressors, duct, and vents. It is extremely easy to use and compact enough to fit in your hand and your tool bag. Designed to withstand a one meter drop, you can count on this lightweight, compact infrared thermometer to work when you need it.

For a 12:1 distance to spot ratio, dual laser targeting check out the Fluke 62MAX+ thermometer.

Other useful features:

  • Provides selectable MAX, MIN, DIF and AVG functions to quickly identify problems
  • One meter drop tested
  • Includes Hi and Lo alarms for rapid display of measurements outside the limits
  • Runs on one (1) AA battery
  • Comes with a one year warranty

Technical Specifications

Specifications
Temperature Range -30°C to 500°C (-22°F to 932°F)
Accuracy (Calibration geometry with ambient temperature 23°C ±2°C)
≥ 0°C ±1.5°C or ±1.5% of reading, whichever is greater
≥ -10°C to < 0°C: ±2.0°C
< -10°C ±3.0°C
≥ 32°F ±3.0°F or ±1.5% of reading, whichever is greater
≥ 14°F to < 32°F ±4.0°F
< 14°F: ±6.0°F
Response Time (95%) < 500 ms (95% of reading)
Spectral Response 8 mm to 14 mm
Emissivity 0.10 to 1.00
Distance to Spot Ratio 10:1 (calculated at 90% energy)
Display Resolution 0.1°C (0.2°F)
Repeatability (% of reading) ±0.8% of reading or ±1.0°C
(±2.0°F), whichever is greater
Power 1 AA IEC LR06 Battery
Battery Life 12 hours with laser and backlight on
Weight 220 g (7.76 oz)
Size 156 x 80 x 50 mm (6.14 x 3.15 x 2 in)
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -20°C to +60°C (-4°F to 140°F), (without battery)
Operating Humidity 10% to 90% RH non-condensing @ 30°C (86°F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
Drop Test 1 m
Ingress Protection Rating IP40 per IEC 60529
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
Compliance EN/IEC 61010-1
Laser Safety FDA and EN 60825-1 Class II
Electromagnetic Compatibility 61326-1 EN 61326-2

Models

Fluke 59 MAX+

Fluke 59 MAX+ Infrared Thermometer
Infrared Thermometer, 10:1 spot

Resources